{"id":30,"date":"2014-05-01T17:07:19","date_gmt":"2014-05-01T17:07:19","guid":{"rendered":"http:\/\/finalroof.abstractwebhost.com\/?page_id=30"},"modified":"2026-05-19T14:32:23","modified_gmt":"2026-05-19T18:32:23","slug":"roofing-ventilation-systems","status":"publish","type":"page","link":"https:\/\/staging.abstractwebhost2.com\/doubleaa\/product-info\/roofing-ventilation-systems\/","title":{"rendered":"Roofing Ventilation and Insulation Systems"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\"><span class=\"style4\">Roofing Ventilation Increases The Life Cycle Of Your Roof.<\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Research has shown that the best way to ventilate an attic is with a system that provides continuous airflow along the entire underside of the roof sheathing. Achieving this desired airflow requires a balanced system of intake ventilation low at the roof\u2019s edge or in the soffit\/eaves and exhaust ventilation at the ridge. Double AA Metal Roofing offers a wide array of venting options for your home or structure. Our Roofing Specialists will assess your current ventilation setup and make recommendations to enhance or replace your system.&nbsp;Double AA Metal Roofing recommends 1 square foot of ventilation for every 150 square feet of attic floor space with half the ventilation represented by intake vents and half by exhaust vents such as ridge vents.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><em>Roofing Ventilation<\/em> Systems <\/strong>help with both the performance and&nbsp;appearance of your home. Years of research have proven that ridge vents combined with sufficient intake vents is usually the most efficient and effective <span style=\"text-decoration: underline;\">roofing ventilation<\/span> system you can install. This balanced system of intake and exhaust through the attic provides greater airflow than any other non-powered vent systems-and it\u2019s the most attractive system visually. In most cases, they blend in nicely with the roof line for great curb appeal.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Roofing Ventilation Systems Comparison<\/h3>\n\n\n\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;6b03234c50004&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"6b03234c50004\" class=\"wp-block-image aligncenter wp-lightbox-container\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"375\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on--pointerdown=\"actions.preloadImage\" data-wp-on--pointerenter=\"actions.preloadImageWithDelay\" data-wp-on--pointerleave=\"actions.cancelPreload\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"http:\/\/finalroof.com\/wp-content\/uploads\/2014\/05\/why_ridge_vents_lrg.png\" alt=\"why_ridge_vents_lrg\" class=\"wp-image-79\" srcset=\"https:\/\/staging.abstractwebhost2.com\/doubleaa\/wp-content\/uploads\/2014\/05\/why_ridge_vents_lrg.png 800w, https:\/\/staging.abstractwebhost2.com\/doubleaa\/wp-content\/uploads\/2014\/05\/why_ridge_vents_lrg-300x141.png 300w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\tdata-wp-bind--aria-label=\"state.thisImage.triggerButtonAriaLabel\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.thisImage.buttonRight\"\n\t\t\tdata-wp-style--top=\"state.thisImage.buttonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Roofing Ventilation<\/strong> is the most important part of keeping your roof trouble free. Contact Us Today for a <a href=\"http:\/\/finalroof.com\/contact-us\/\">Free Estimate<\/a> to see what\u00a0<strong>Roofing Ventilation System<\/strong> will work \u00a0for you and your home.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Attic Insulation Increases the Life Cycle of Your Roof.<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In addition to helping with your roofing needs, our Metal Roofing Specialists will also help to guide&nbsp;you&nbsp;in your insulation needs. As roofers, we know the importance of reducing condensation in your attic. Proper insulation will not only lower heating and cooling costs, but by reducing condensation, the chance of mold and mildew buildup will also decrease.<\/p>\n\n\n\n<figure data-wp-context=\"{&quot;galleryId&quot;:&quot;6b03234c501c9&quot;}\" data-wp-interactive=\"core\/gallery\" class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;6b03234c502c4&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"6b03234c502c4\" class=\"wp-block-image size-large wp-lightbox-container\"><img loading=\"lazy\" decoding=\"async\" width=\"726\" height=\"391\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on--pointerdown=\"actions.preloadImage\" data-wp-on--pointerenter=\"actions.preloadImageWithDelay\" data-wp-on--pointerleave=\"actions.cancelPreload\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" data-id=\"892\" src=\"https:\/\/staging.abstractwebhost2.com\/doubleaa\/wp-content\/uploads\/2015\/07\/summer_attic.png\" alt=\"summer_attic\" class=\"wp-image-892\" srcset=\"https:\/\/staging.abstractwebhost2.com\/doubleaa\/wp-content\/uploads\/2015\/07\/summer_attic.png 726w, https:\/\/staging.abstractwebhost2.com\/doubleaa\/wp-content\/uploads\/2015\/07\/summer_attic-300x162.png 300w\" sizes=\"auto, (max-width: 726px) 100vw, 726px\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\tdata-wp-bind--aria-label=\"state.thisImage.triggerButtonAriaLabel\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.thisImage.buttonRight\"\n\t\t\tdata-wp-style--top=\"state.thisImage.buttonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><\/figure>\n\n\n\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;6b03234c50471&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"6b03234c50471\" class=\"wp-block-image size-large wp-lightbox-container\"><img loading=\"lazy\" decoding=\"async\" width=\"726\" height=\"391\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on--pointerdown=\"actions.preloadImage\" data-wp-on--pointerenter=\"actions.preloadImageWithDelay\" data-wp-on--pointerleave=\"actions.cancelPreload\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" data-id=\"886\" src=\"https:\/\/staging.abstractwebhost2.com\/doubleaa\/wp-content\/uploads\/2015\/07\/winter_attic.png\" alt=\"winter_attic\" class=\"wp-image-886\" srcset=\"https:\/\/staging.abstractwebhost2.com\/doubleaa\/wp-content\/uploads\/2015\/07\/winter_attic.png 726w, https:\/\/staging.abstractwebhost2.com\/doubleaa\/wp-content\/uploads\/2015\/07\/winter_attic-300x162.png 300w\" sizes=\"auto, (max-width: 726px) 100vw, 726px\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\tdata-wp-bind--aria-label=\"state.thisImage.triggerButtonAriaLabel\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.thisImage.buttonRight\"\n\t\t\tdata-wp-style--top=\"state.thisImage.buttonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><\/figure>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;&nbsp;&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Double AA Metal Roofing&#8217;s systems automatically reduce the heating and cooling costs in your home as they reflect sun in the summer and insulate from the cold in the winter. To increase this benefit, adding the proper insulation in your attic will make your home cooler in the summer and warmer in the winter. As heat rises in the winter into your attic, it is important to keep the heat inside to avoid paying more for comfort. As the heat attempts to penetrate your home in the summer, attic insulation will not allow the heat to penetrate into your living space as much.<\/p>\n\n\n\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;6b03234c50c9d&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"6b03234c50c9d\" class=\"wp-block-image alignright wp-lightbox-container\"><img loading=\"lazy\" decoding=\"async\" width=\"293\" height=\"300\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on--pointerdown=\"actions.preloadImage\" data-wp-on--pointerenter=\"actions.preloadImageWithDelay\" data-wp-on--pointerleave=\"actions.cancelPreload\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"http:\/\/finalroof.com\/wp-content\/uploads\/2015\/07\/Insulation-293x300.png\" alt=\"Insulation\" class=\"wp-image-879\" srcset=\"https:\/\/staging.abstractwebhost2.com\/doubleaa\/wp-content\/uploads\/2015\/07\/Insulation-293x300.png 293w, https:\/\/staging.abstractwebhost2.com\/doubleaa\/wp-content\/uploads\/2015\/07\/Insulation.png 607w\" sizes=\"auto, (max-width: 293px) 100vw, 293px\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\tdata-wp-bind--aria-label=\"state.thisImage.triggerButtonAriaLabel\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.thisImage.buttonRight\"\n\t\t\tdata-wp-style--top=\"state.thisImage.buttonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Things to Know About Attic Insulation<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The attic is often the most cost-effective place to add insulation. Typically, a contractor will blow loose fill into and over the top of ceiling joists. Batts laid sideways over existing insulation is an alternative choice for the do-it-yourselfer.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The air barrier at the ceiling line must be tight to ensure warm moist air from the house does not get into the cold attic and condense in the winter (this is critical). Check ceiling light fixtures, the tops of interior walls and penetrations such as plumbing stacks for air leakage. The picture to the right gives an idea of where air can leak into the attic.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It is also critical to ensure that your soffit venting is not blocked by the insulation that you add. Baffles or Moore Vents may have to be installed to ensure proper air flow.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Roofing Ventilation Increases The Life Cycle Of Your Roof. Research has shown that the best way to ventilate an attic is with a system that provides continuous airflow along the entire underside of the roof sheathing. Achieving this desired airflow requires a balanced system of intake ventilation low at the roof\u2019s edge or in the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":26,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-30","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/staging.abstractwebhost2.com\/doubleaa\/wp-json\/wp\/v2\/pages\/30","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/staging.abstractwebhost2.com\/doubleaa\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/staging.abstractwebhost2.com\/doubleaa\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/staging.abstractwebhost2.com\/doubleaa\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/staging.abstractwebhost2.com\/doubleaa\/wp-json\/wp\/v2\/comments?post=30"}],"version-history":[{"count":1,"href":"https:\/\/staging.abstractwebhost2.com\/doubleaa\/wp-json\/wp\/v2\/pages\/30\/revisions"}],"predecessor-version":[{"id":10714,"href":"https:\/\/staging.abstractwebhost2.com\/doubleaa\/wp-json\/wp\/v2\/pages\/30\/revisions\/10714"}],"up":[{"embeddable":true,"href":"https:\/\/staging.abstractwebhost2.com\/doubleaa\/wp-json\/wp\/v2\/pages\/26"}],"wp:attachment":[{"href":"https:\/\/staging.abstractwebhost2.com\/doubleaa\/wp-json\/wp\/v2\/media?parent=30"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}